Installation & Maintenance Instructions
TABLE OF CONTENTS
I. UNCRATING.......................................................................................................................................................................................................... 2
II. GENERAL MOUNTING INSTRUCTIONS ...........................................................................................................................................................2
III. WALL MOUNTING .............................................................................................................................................................................................2
IV. SUSPENDED MOUNTING ................................................................................................................................................................................ 3
V. ELECTRICAL CONNECTIONS ........................................................................................................................................................................ ....4
VI. FIELD CONNECTIONS ......................................................................................................................................................................................6
VII. OPERATION INSTRUCTIONS ......................................................................................................................................................................... 6
VIII. MAINTENANCE AND CLEANING ................................................................................................................................................................. 7
IX. SERVICE ............................................................................................................................................................................................................ 7
INTELLISWITCH®...................................................................................................................................................................................................10
QUICK START OPERATION.......................................................................................................................................................................... .10
FAQ’s (FREQUENTLY ASKED QUESTIONS)................................................................................................................................................ 12
THE INTELLISWITCH® PROGRAMMING)....................................................................................................................................................14
X. TROUBLESHOOTING........................................................................................................................................................................................19
XI. WARRANTY ......................................................................................................................................................................................................20
www.intelli-how2.com 800-245-4455 www.berner.com
IMPORTANT INSTRUCTIONS
READ AND SAVE
THESE INSTRUCTIONS
No. II-470
Date May, 2014
Saving energy and creating healthy, comfortable environments
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Read all instructions before installing or using this air curtain.
B. Use this unit only in the manner intended by the manufacturer and described in this manual. Any other use not recommended by the
manufacturer may cause re, electric shock, or injury to persons. If you have any questions, contact the manufacturer.
C. Before servicing or cleaning unit, switch power o at service panel and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
D. Installation work and electrical wiring must be done by qualied person(s) in accordance with all applicable national and local codes
having jurisdiction, including re-rated construction. See page 4, ELECTRICAL CONNECTIONS (NEC Code ANSI/NFPA No. 70).
E. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
F. To reduce the risk of re, do not store or use gasoline or other ammable vapors and liquids in the vicinity of the air curtain.
G. This air curtain is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials, such as furniture,
pillows, bedding, papers, clothes, etc. and curtains at least 1 inch from the top, back, front, sides and at least 6 feet from the discharge of
the air curtain.
H. Extreme caution is necessary when any air curtain is used by or near children or invalids, and whenever the heater is left operating
unattended.
I. Do not operate any air curtain after it malfunctions. Disconnect power at the service panel and have the air curtain inspected by a
reputable electrician before reusing.
J. To disconnect the air curtain, turn controls to "o", and turn o power to the air curtain circuit at main disconnect panel.
K. Do not insert or allow foreign objects to enter any ventilation or discharge opening as this may cause an electric shock or re, or damage
the air curtain.
L. To prevent a possible re, do not block the air intake or discharge of the air curtain in any manner.
M. The air curtain has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or ammable vapors or liquids are
used or stored.
N. This heater may include an audible or visual alarm to warn that parts of the heater are getting excessively hot. If the alarm sounds (or
illuminates), immediately turn the heater o and inspect for any objects on or adjacent to the heater that may have blocked the airow or
otherwise caused high temperatures to have occurred. DO NOT OPERATE THE HEATER WITH THE ALARM SOUNDING (OR ILLUMINATING).
ARCHITECTURAL
Low Prole 8
AIR CURTAIN SERIES ALC08
FDA
RECOMMENDED
USDA
COMPLIANCE
Vedere la pagina 0
1 2 3 4 5 6 ... 19 20

Sommario

Pagina 1 - ARCHITECTURAL

Installation & Maintenance Instructions TABLE OF CONTENTSI. UNCRATING...

Pagina 2 - III. WALL MOUNTING

How to operate your Architectural Low Prole 8 Air Curtain that comes with a factory installed digital programmable controller called the Intelliswitc

Pagina 3 - IV. SUSPENDED MOUNTING

PLUS“PluS”COMFORT PLUSFor use on heated units only, requires a door switch. When the temperature drops below the thermostat set point and the door is

Pagina 4 - V. ELECTRICAL CONNECTIONS

INTELLISWITCH™ FAQ’s (Frequently Asked Questions)12Q. Why can’t I change my settings? A. The Intelliswitch™ may be locked. If the Lock light is illumi

Pagina 5

heat should shut o when the wires are separated. For more complex troubleshooting of either thermal cutouts or heater contactors, please consult a qu

Pagina 6 - VII. OPERATING INSTRUCTIONS

Note: The OK button always saves the current entered value and returns you to the User Menu display clock.Section 1: Quick Start ReferenceSecti

Pagina 7 - IX. SERVICE

active for AUTO, DELU and PLUS Mode.Note: to turn o this feature the Start Time must be set equal to Stop Time (including am/pm).4.8. Thermostat Mode

Pagina 8

The Program menu allows parameters for the following options to be set: • Number of Zones: 1 or 2 • Days of the week to operate per zone • Mode (O

Pagina 9

Appendix - 17Er 51 – Status of this error is not available. It only appears when there has been an event that has corrupted the settings in memory. Wh

Pagina 10 - To operate the air door:

Appendix - 188.2. Heat Mode ActivationWhen terminals 6 and 7 in the junction box are connected (closed), the Heat Mode is activated for all Operating

Pagina 11 - Modes of Operation continued:

• Air stream too weak • Air steam hits obstruction• Negative pressure• Shaft rotating inside fan• One motor not operating• Nozzle not angled o

Pagina 12

I. UNCRATINGCarefully examine the carton(s) for damage. If the carton is damaged, immediately notify the shipping company. Do not delay in ling clai

Pagina 13

XI. WARRANTYBerner International (“The Company”) warrants all new equipment to be free of defects in workmanship and material for a period of ve year

Pagina 14 - Appendix -14

B. Determine the exact mounting location of the air curtain. NOTE: A minimum of 1” is required above the wall mounting plate to provide clearance

Pagina 15 - Appendix - 15

tray or it may be located outside of the air curtain. If the air curtain is unheated, or the sensor will be left in the wiring tray, skip to s

Pagina 16 - Appendix -16

Electrical KnockoutsWiring Tray CoverElectrical Rating NameplateWiring Diagram and Temperature Sensor InsideFIGURE 7 - Electrical Connections NOTE: O

Pagina 17 - Appendix - 17

Note: If a longer cable is required than was supplied, it can be ordered from the factory or made by using standard at telephone cable, phone jack

Pagina 18 - Appendix - 18

IX. SERVICE CAUTION: ELECTRIC SHOCK HAZARD Disconnect power whenever servicing unit. More than one disconnect may be required to de-energize uni

Pagina 19 - X. TROUBLESHOOTING

NOTE: GROUND RING TERMINAL MUST BE SITUATED OR BEND SUCH THAT IT DOES NOT TOUCH ANY TRACES ON THE CONTROL BOARD 11. Continue installing the new c

Pagina 20 - XI. WARRANTY

14. Install the trigger bar on the replacement motor so that it is not closer than 0.030” to the motor bearing cap (including shaft movement